How do I configure the KPI: Mean Time To Repair?

How do I configure the KPI: Mean Time To Repair?

The standardized KPI, 'Mean Time To Repair', can be monitored via the KPI Details page and also via the MTTR Report. Here you learn how to configure it in the Admin app.

From the KPI panel on the machine page, click on the menu option ‘Configuration’ for Mean Time to Repair. You will then be taken to the configuration page.
Here you need to select an appropriate sensor to provide input data for the formula:

MTTR = Downtime / Number of repairs



1. Status (availability): This sensor needs to be supplying data on the current status of your machine. Is it actively running or not? The virtual or physical sensor need to provide the following values: "0" for "OFF", "1" when the machine is operating normally, "2" if the machine is in failure.

2. The target panel allows you to assign a target value, which you want your MTTR to achieve.

3. The thresholds behave like sensor thresholds, when the MTTR crosses a threshold an event will be triggered, which will be displayed in the KPI timeline, and may trigger a notification if these are enabled.  Keep in mind that because you want the MTTR to be as low as possible, the cautionary threshold should be a higher value than the 'target'; and the emergency value, should be higher than the cautionary value.

Once this is done, you have enough to click save, upon which your KPI will become active.

    • Related Articles

    • MTTR Report

      The MTTR Report allows you to view the Mean Time To Repair data per hour, day, or week, depending on the selected timeframe. Remember: The MTTR KPI, is a measure of how long it is taking to conduct repairs and get equipment and production lines ...
    • How do I configure the KPI: Mean Time Between Failure?

      The standardized KPI, 'Mean Time Between Failure', can be monitored via the KPI Details page and also via the MTBF Report. Here you learn how to configure it in the Admin app. From the KPI panel on the machine page, click on the menu option ...
    • How to configure a time-based sensor

      A time-based sensor acts like a physical sensor in the sense that it produces data, but the data generated is based on a schedule. To create a time-based sensor for your machine, you first need to define it. Do this in the Admin app by selecting the ...
    • Shift Configuration

      Shifts can be configured in the Admin app. Shifts are an important part of efficiently operating machinery. Configuring your shifts in innius will allow you to view data in relation to your shifts, namely sensor data and the KPI data like the Overall ...
    • How do I configure the KPI: Overall Equipment Effectiveness?

      From the KPI panel on the machine page, click on the menu option ‘Configuration’ for Overall Equipment Effectiveness. You will then be taken to the configuration page. Here you need to select appropriate sensors to provide suitable input data for ...